CARGOMASTER®5
63 - Operators Manual
D
Draft values
L
Line pressures
Other commands
Keys / Codes
Function
AO
Alarm Overview
AA
Alarm Acknowledge
AS
Alarm Silence
US
US Units
US1
US Units (Fahrenheit, BBLS, Lton)
US2
US Units (Fahrenheit, USGallon, Lton)
US3
US Units (Fahrenheit, BBLS, Lton, Density in Vacuum)
US4
US Units (Fahrenheit, USGallon, Lton, Density in Vacuum)
SI
SI Units
SI1
SI Units (Density in Air)
SI2
SI Units (Density in Vacuum)
Up/Down arrows
Next / Previous page
PageUp / PageDown
Next / Previous page
Left / Right arrows
Select Unit type
Redraw
Redraw previous page
Help or ?
Help
Change Unit
To change displayed units, use the following codes:
Code
Function
Code
Function
LEV
Level
IGP
Inert Gas Pressure
ULL
Ullage
MD
Measured density
VOL
Volume
MDO
Measured Density On/Off
V%
Volume percentage
RT1
Reference Temperature 1
DNS
Density
RT2
Reference Temperature 2
WGT
Weight
EXP
Expansion Coefficient
LRT
Loadrate
APT
API type
OD1
Operator density 1
API
API
OD2
Operator Density 2
HHV
HiHi Volume Limit
TP
Top Pressure
HIV
Hi Volume Limit
BP
Bottom Pressure
LOV
Lo Volume Limit
UP
Upper Pressure
HIT
Hi Temperature Limit
MP
Mid Pressure
LOT
Lo Temperature Limit
TT
Top Temperature
HII
Hi Inertgas Pressure Limit
BT
Bottom Temperature
LOI
Lo Inertgas Pressure Limit
UT
Upper Temperature
DIF
Density Difference
MT
Mid Temperature
LPR
Line Pressure
XT1-
XT5
Extra Temperature Elements 1-5
VPR
Vapor Pressure
Note that several of these units are optional, and may not be installed.
The values that the operator can change via the Terminal program are:
LEVEL, ULLAGE, VOLUME, DENSITY, WEIGHT, TEMPERATURE,
OPERATOR DENSITY 1 (OD1) and OPERATOR DENSITY 2 (OD2).