beautypg.com

Technical data, 5 dynamic output behaviour – KROHNE OPTIBAR PC 5060 C EN User Manual

Page 69

background image

TECHNICAL DATA

7

69

OPTIBAR PC 5060 C

www.krohne.com

04/2014 - 4003437201 - MA OPTIBAR PC 5060 C R01 en

7.5 Dynamic output behaviour

These parameters depend on the filling medium, temperature and, if applicable, the chemical
seal.

Figure 7-3: Behaviour for an sudden change of the process variable.
t

1

- dead time; t

2

- rise time; t

3

- step response time

1 Process variable
2 Output signal

Dead time (t1)

> 45 ms

Rise time (t2)

> 35 ms (10...90%)

Step response time (t3)

> 80 ms (ti: 0 seconds, 10...90%)

Damping (63% of input variable)

0...999 seconds, adjustable

.book Page 69 Friday, May 2, 2014 12:49 PM