beautypg.com

Service – KROHNE OPTIBAR PC 5060 C EN User Manual

Page 57

background image

SERVICE

6

57

OPTIBAR PC 5060 C

www.krohne.com

04/2014 - 4003437201 - MA OPTIBAR PC 5060 C R01 en

6.8 Exchange process assembly for IP 68 (25 bar) version

In the case of the IP 68 (25 bar) version the user can change the process assembly on site. The
connection cable and external housing can be retained.

Required tool:

• Size 2 Allen wrench

1. Loosen fixing screw with Allen wrench
2. Carefully remove the cable assembly from the process assembly
3. Loosen connector
4. Mount new process assembly on the measuring station
5. Reassemble connector
6. Insert cable assembly on process assembly and rotate to desired position
7. Tighten fixing screw using Allen wrench

This completes the replacement

DANGER!
For devices used in hazardous areas, additional safety instructions apply.

DANGER!
All work on the electrical connections may only be carried out with the power disconnected. Take
note of the voltage data on the nameplate!

Figure 6-1: IP 68 version 25 bar (external housing)

1 Process assembly
2 Connector
3 Fixing screw
4 Cable assembly
5 Connection cable
6 External housing

.book Page 57 Friday, May 2, 2014 12:49 PM