2.1 Device description
TDR level meters are designed exclusively to measure the distance and level of liquids, pastes,
slurries, powders and granulates.
Your measuring device is supplied with a standard length of probe. If the probe length is larger
than the tank height, you must adjust the length of the probe to the tank height before operation.
A quick set-up procedure permits the device to operate correctly with the new probe length.
The following versions are available:
• Compact version with Ø2 mm / 0.08¨ single cable probe (for liquids)
• Compact version with coaxial probe (for liquids, maximum viscosity 500 mPa.s / 0.028 lb/in.s)
• Compact version with Ø4 mm / 0.15¨ single cable probe (for solids)
2.2 Nameplates
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
Figure 2-1: Nameplate
1 Cable entry size
2 Date of manufacture
3 Degree of ingress protection (according to EN 60529 / IEC 60529)
4 Order number
5 Type code (defined in order)
6 Model name and number
7 Company name and address