HARDWARE DETAILS

05

5 .4 .3 Serial Communication Connection

A serial port is available on all I/O boards and terminal connections are universal for digitals,

analogue and switch I/O boards.

Figure 30 Serial port I/O boards rear terminal pin allocation

5 .5 Digital I/O Board

The digital I/O board 1 can only be exchanged by qualified personnel. Up to a maximum of 6

cards can be inserted in any of the plug in slots in the SUMMIT 8800 chassis. A board can provide

input and output functions as detailed:

• 3 pulse counting/frequency measuring inputs (for use with turbine meters, rotary meters,

density or relative density transducers).

• 2 digital status inputs for use with switch or contact inputs.

• 2 Smart transmitter (HART) loops. Each loop can provide connections for up to 3 transmitters

each with four variables such as pressure, temperature or differential pressure transmitters.

• 1 Direct 4 wire RTD input for direct measurement of temperature.

• 5 digital transistor switched outputs for use in telemetry systems or for alarm indication.

• 2 analog 4-20 mA outputs for use in telemetry or control systems.

• 1 Serial communication port using either (RS232 or half duplex RS485), providing connection

to gas meters, gas chromatographs or other equipment that transfers data via serial commu-

nication.