INSTALLATION AND REPLACEMENT

04

Some parts of the instrument such as circuit boards may be damaged by static electricity. When

handling internal parts of the instruments, ensure that anti-static precautions are taken. It is

therefore essential when carrying out any maintenance or installation work that an earthed

wrist strap be worn, or other such precautions, whenever internal parts of the instrument are

handled.

4 .2 .2 Earthing Requirements

The SUMMIT 8800 must be connected to a suitable ground or earth connection via the M4 earth

stud located at the rear of the chassis. See below for details.

4 .2 .3 Fuses and Battery

The SUMMIT 8800 has an internal fuse F1 and an externally accessible fuse F2 on the rear

panel. Fuse F1 protects the DC input circuits and can only be replaced by qualified personnel.

Isolate the main power to the SUMMIT 8800. Remove the rear panel as specified under Hard-

ware Details. Withdraw the PSU board and identify F1 as detailed in the figure below. Replace

fuse F1 only with a replacement fuse type:

Fuse F2 protects the DC output and can be replaced by all personnel. Isolate the main power