beautypg.com

3 .3 integration possibilities, 3 .2 .2 calculations & compliance standards, 3 .3 .1 system integration – KROHNE Summit 8800 Vol 1 User Manual

Page 22

background image

22

www.krohne.com

08/2013 - MA SUMMIT 8800 Vol1 R02 en

SUMMIT 8800

DESCRIPTION

03

• Pulse handling: API5.5 level A, B, C, D, E, Dual chronometry, pulse interpolation

• Calibration up to 20 points linear, meter factor or K-curve, 5 products (future at present 1)

• Density/ specific gravity: frequencies Solartron 781x, 783x, Sarasota ID900

• Counters: Unhaltable, Normal, Period, Error, Maintenance, Positive and negative, Prover

• Averages: Time weighted, Flow weighted.

• Provers: Bi-directional, 2 / 4 detector inputs, piston prover, master provers

• Control: up to 18 valves, Prover, PID

• TCP/IP and serial Modbus protocols for

Ultrasonic meters: KROHNE AIII, AV, V12, Daniel, Elster, GE, Sick

Chromatographs: ABB, Daniel, Elster, Siemens

• And custom configurable protocols.

3 .2 .2 Calculations & Compliance standards

AGA3

(Orifice meters) gas flow calculations.

AGA5

(Natural Gas Energy Measurement)

AGA7

(Measurement of Natural Gas by Turbine Meter)

AGA8

(Compressibility Factor of Natural Gas and Related Hydrocarbon Gases)

AGA9-support

(Measurement of Gas by Multipath Ultrasonic Meters)

AGA10

(Speed of Sound in Natural Gas and Other Related Hydrocarbon Gases)

API MPMS (Manual of

Petroleum Measurement

Standards):

Chapter 5.6 (Measurement of Liquid Hydrocarbons by Coriolis Meters)
Chapters 11.1, 11.2, 21.1 & 21.2 etc
Chapters 12.2.5.1 & 2
Chapter 12.2.5.3 Table 54, 54A, 54B, 54D

API 2540
ASTM D1250 IP200
GPA 2172, TP-27
GOST NX19
ISO 5167 (2003 , 1997, 1991)
ISO 6976
NX19, NX19 G9
OIML R117-1 Edition 2007
PTZ, NX19, NX19 G9, SGERG

(all types), User-defined Z-factor Tables, fixed

SGERG

(all types)

WELMEC guide 8.8

... and more to come

3 .3 Integration possibilities

3 .3 .1 System Integration

The SUMMIT 8800 can be integrated as a component within a fully automated system.

When within a system, the SUMMIT 8800 is usually an intermediate device interacting with all

field devices and supervisory systems.