4. Installation and Replacement
Please read these instructions carefully before assembling or installing this product to avoid
danger to people, pets and damage to connecting devices and the SUMMIT 8800. Installation of
this product may only be performed by qualified personnel.
The SUMMIT 8800 comes with all links and internal switches set to factory default see Chapter
Hardware Details: Rear panel Mode Switches.
Before any power or signal connections are applied to the SUMMIT 8800 the qualified personnel
should ensure that all links are set at the correct position for the appropriate and intended use.
Failure to do so may result in damage to the SUMMIT 8800 and any associated equipment.
The flow computer device is powered with +24VDC.
Do not touch any of the internal components whilst the unit is powered.
Turn off the power to the SUMMIT 8800 before opening the device or installing the product.
Only energize the device when it is wired, installed and all covers are securely in place.
4 .1 Mechanical Specifications
4 .1 .1 Mechanical Installation
All installation tasks should be performed by qualified personnel. The external chassis dimen-
sions (for panel or rack mounting) are given in the figure below. Ensure that the ventilation
slots on the upper and lower surfaces on the SUMMIT 8800 are kept clear from any obstruction.
Ensure that ventilation and shading is provided when the SUMMIT 8800 is subjected to high
ambient temperatures (such as being near heat producing apparatus) or to direct sunlight. The
operating environment must be clean, dry and free from corrosive elements.
NOTE: When used as part of MID approval which states the use of the SUMMIT 8800 to be
indoors and in a controlled environment where it is subject to the requirements of EN 12405,
the SUMMIT 8800 must be mounted in an enclosure with an ingress protection rating of IP65 or
better.
Front