15 .4 data sheet, 15 .3 .2 power supply – KROHNE Summit 8800 Vol 1 User Manual
Page 135
135
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol1 R02 en
SUMMIT 8800
APPENDIX 3: TECHNICAL DATA
15
Serial Communication
Physical Layer
RS232 or RS485
Max Baud Rate
38400 baud
Handshake
RTS/CTS on Port PL3
None on Port PL4 or PL5
Isolation
Galvanically isolated
Network communication
Ethernet
IEEE 802.3
Speed
10/100
15 .3 .2 Power Supply
Power Input
Voltage Range
+24VDC +/- 10%
Power Consumption
All slots occupied
30W at Input voltage +24V nominal
1 I/P Board and 1 comms
Board
8.5W
Fuse
F1 Internal
3.15A 20mm
F2 External Rear Panel
1.6A 20mm
Power Output
Rear Aux Connector
+24V DC nominal at I max = 200mA
15 .4 Data sheet
SUMMIT 8800 Flow Computer Specifications.
Overview
Number of runs
Up to 5 runs plus a prover/master meter
Calculation cycle
0.25, 0.5 or ¼ second
Communication
Single or dual ethernet to SCADA, serial ports to meters, DCS, PLC, GC and
analysers
Audit trail/ logging
Full audit trail with defined user name, logging/ trending e.g. lifetime data,
recorded 7 times per minute on 4 GB flash memory card
Products
Oil, liquids, water, gas, wet gas, steam, LPG, LNG, industrial gases, CO2 emis-
sion, etc.
Hardware
Chassis
Half width 3U high 19” construction
Panel or chassis mounted
Dimensions 130 x 210 x 240 mm (h x w x d)
Accommodates up to 6 plug-in cards
IP20 Ingress protection index level
IP52 in a panel with open doors
IP 65 in an appropriately closed panel
Power supply
Supply voltage 22 to 28 V DC 8.5 W (15 W with 6 boards fitted)
Protection 3.15A internal fuse
Protection 1.6A external fuse
Auxiliary outputs 24 VDC/ 200 mA
Operating
Operating temperature
-10 to 55 °C analog inputs (15 to 130 °F)
-25 to 55 °C HART inputs (-15 to 130°F)
Storage temperature
-20 to 70 °C (0 to 160 °F)
Operating humidity
30% to 90% non-condensing
Weight approximately
2.0 kg / 4.5 lbs
(2.5 kg / 5 lbs with 6 boards fitted)
Rear Panel