KROHNE Summit 8800 Vol 1 User Manual
Page 136
136
www.krohne.com
08/2013 - MA SUMMIT 8800 Vol1 R02 en
SUMMIT 8800
APPENDIX 3: TECHNICAL DATA
15
Field connections
PSU connections and fuse
Six slots for option boards
I/O and Communication Connections
Switch Panel
Access to security mode switches
Access to Memory Card
Front Panel Display
Display
5.7” Colour graphics screen
Touch panel
360° rotary facilitating menu navigation dial
Local language support
5 x high brightness indicator LED’s
Front panel USB connection
Various
Configuration
Menu-based configuration program
Optional “flow computer” language interpreter
Local data downloading via USB
Local diagnostics and re-programming
Connectors
RS232/485 RJ45
Ethernet 10/100 Mbs RJ45
Connector kit to rail mounted screw terminal
I/O board Weidmüller non-screw type 36-way (part no 1748640000)
Power in Weidmüller connector (part no 1727570000)
Power out Weidmüller connector (part no 1597370000)
Meters and Standards
Meter technology
Pulse: e.g. Turbine, PD, Prover,
DP: e.g. Orifice, Venturi
Serial: e.g. Ultrasonic, Coriolis
Connectivity
Meters: Turbine, Coriolis, PD, Ultrasonic, Orifice, Venturi, Nozzle, etc.
Ultrasonic meters: KROHNE, Daniel, Elster, GE, Sick, etc.
Chromatographs: ABB, Daniel, Elster, Siemens, etc.
Density/ specific gravity: frequencies Solartron 781x, 783x, Sarasota ID900
Provers: Bi-directional, 2 / 4 detector inputs, piston prover, master provers
Control: up to 18 valves, Prover, PID
Approvals
Compliant with all international approvals, including
- MID European approval
- CSA C22.2, CB, CCSAus
- UL 61010-1, IEC 61000-4, IEC 61010-1, EN G1326-1
- OIML R117
Standards
Compliant with international standards, including
ISO 5167 (2003 , 1997, 1991), ISO 6976,
PTZ, NX19, NX19 G9, SGERG (all types), User defined Z-factor Tables, Fixed
AGA3, 5, 7, 8, 9-support, 10, 11
API chapters 11.1, 11.2 and 21.112.2.5.1 and 2, chapters 12.2.5.3 Table 54 and
54A
ASTM D1250 IP200
OIML R 022
GPA 2172
GOST NX19
Processing
Calibration up to 20 points linear (positive and/or negative), meter factor or
K-curve, 5 products
Pulse handling: API5.5 level A, B, C, D, E, dual chronometry, pulse interpola-
tion
Counters: Unhaltable, Normal, Period, Error, Maintenance, Positive and nega-
tive, Prover
Averages: Time weighted, Flow weighted