Operation – KROHNE GFC 300 FOUNDATION FIELDBUS User Manual

Page 58

background image

4

OPERATION

58

GFC 300

www.krohne.com

07/2012 - 4001866001 - AD GFC 300 FF R01 en

GAIN_IN_2

GAIN_IN_2

GAIN_IN_2

GAIN_IN_2

Gain Input 2

Gain Input 2

Gain Input 2

Gain Input 2

R/W

The constant to be multiplied times (IN_2 + bias).

0

GAIN_IN_3

GAIN_IN_3

GAIN_IN_3

GAIN_IN_3

Gain Input 3

Gain Input 3

Gain Input 3

Gain Input 3

R/W

The constant to be multiplied times (IN_3 + bias).

0

GRANT_DENY

GRANT_DENY

GRANT_DENY

GRANT_DENY

Grant Deny

Grant Deny

Grant Deny

Grant Deny

Options for controlling access of host computers and local

control panels to operating, tuning and alarm parameters of

the block.

-

GRANT

Grant

R/W

Depending on the philosophy of the plant, the operator or a

higher level device (HLD) or a local operator's panel (LOP) in

the case of "Local", may turn on an item of the "Grant"

attribute - "Program, Tune, Alarm or Local".

Uninitialized

Setting:

Program / Tune / Alarm / Local / Operate

DENY

Deny

The deny attribute is provided for use by a monitoring

application in an interface device and may not be changed by

an operator.

Setting:

Program denied / Tune denied / Alarm denied / Local denied /

Operate denied

IN

IN

IN

IN

Input

Input

Input

Input

Primary input value of the block, required for blocks that filter

the input to get the PV.

Status

R/W

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

Value

R/W

A numerical quantity entered by a user or calculated by the

algorithm.

-

IN_LO

IN_LO

IN_LO

IN_LO

Input Low

Input Low

Input Low

Input Low

Input for the low range transmitter in a range extension

application.

Status

R/W

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

Value

R/W

A numerical quantity entered by a user or calculated by the

algorithm.

-

IN_1

IN_1

IN_1

IN_1

Input 1

Input 1

Input 1

Input 1

Auxiliary input value to the block, used for other values than

the PV.

Status

R/W

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

Value

R/W

A numerical quantity entered by a user or calculated by the

algorithm.

-

IN_2

IN_2

IN_2

IN_2

Input 2

Input 2

Input 2

Input 2

Input required by the characterizer.

Status

R/W

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

Value

R/W

A numerical quantity entered by a user or calculated by the

algorithm.

-

IN_3

IN_3

IN_3

IN_3

Input 3

Input 3

Input 3

Input 3

Numbered input required by selector block.

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value