FRAM_DIAG

FRAM Diagnosis

R

Result of FRAM self diagnosis.

ok

Setting:

ok / not supported action / unknown / busy / wait / first init /

changed / bit09 / parameter error / page error / chip error /

write error / warning: inconsistent / warning: uncertain /

warning: write cycles / warning: one header / ok, page high

workLOAD

R

Work load of the processor.

Current work load

DIAGNOSIS_BLK

DIAGNOSIS_BLK

DIAGNOSIS_BLK

DIAGNOSIS_BLK

Diagnosis Block

Diagnosis Block

Diagnosis Block

Diagnosis Block

R

Detailed diagnosis of the blocks.

-

RB_DIAG

RB Diagnosis

R

Reason for bits set at BLK_ERR and other diagnosis.

Current diagnosis

Setting:

Startup Device / RB: MODE_BLK.ACTUAL is OOS / Memory

failure / Operating System / new: ID, DEV_TYPE, SNR / no GDC

Communication / Startup GDC, data invalid / Startup Sensor,

data valid / C-Number doesn't match to FF Software /

Hardware changed, C raw != C detected / Data Base doesn't

match to FF Software / MODE_BLK.PERMITTED doesn't

include Auto / MODE_BLK.TARGET is set OOS / GDC bold F

message / GDC F message / write from GDC to RB/TB doesn't

work / GDC Mfr unknown / GDC serial number / Boardinfo

incomplete or corrupt / action: write from GDC to RB/TB /

GDC W: no, M: no / GDC W: no, M: some /

GDC W: some, M: no / GDC W: no, M: all /

GDC W: all, M: no / GDC W: some, M: some /

GDC W: some, M: all / GDC W: all, M: some /

GDC Communication few loss / RS_STATE is not On-Line /

simulation active / unknown reason / Ok

TB1_DIAG

TB1 Diagnosis

R

Reason for bits set at BLK_ERR and other diagnosis.

Current diagnosis

Startup Device / RB: MODE_BLK.ACTUAL is OOS / Memory

failure / no GDC Communication / Startup GDC, data invalid /

Startup Sensor, data valid / Data Base doesn't match to FF

Software / MODE_BLK.PERMITTED doesn't include Auto /

MODE_BLK.TARGET is set OOS / GDC bold F message / GDC F

message / write from GDC to RB/TB doesn't work / Sensor

serial number / Sensor calibration date / GDC unit not

convertible to TB.prim_val / prim_val is outside range /

action: write from GDC to RB/TB / GDC Communication few

loss / no unit of GDC / GDC unit can't be converted to

TB.prim_range / a GDC value was not received / a GDC short

status is fatal or warn2 / PRIMARY_VALUE_1.status is

Uncertain / unknown reason / Ok

TB2_DIAG

TB 2

R

Reason for bits set at BLK_ERR and other diagnosis.

Current diagnosis

Setting:

Startup Device / RB: MODE_BLK.ACTUAL is OOS / Memory

failure / no GDC Communication / Startup GDC, data invalid /

Startup Sensor, data valid / Data Base doesn't match to FF

Software / MODE_BLK.PERMITTED doesn't include Auto /

MODE_BLK.TARGET is set OOS / GDC bold F message / GDC F

message / write from GDC to RB/TB doesn't work / Sensor

serial number / Sensor calibration date / GDC unit not

convertible to TB.prim_val / prim_val is outside range /

action: write from GDC to RB/TB / GDC Communication few

loss / no unit of GDC / GDC unit can't be converted to

TB.prim_range / a GDC value was not received / a GDC short

status is fatal or warn2 / PRIMARY_VALUE_1.status is

Uncertain / temperatur input / pressure input / p & T input /

unknown reason / Ok

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value