Operation – KROHNE GFC 300 FOUNDATION FIELDBUS User Manual
Page 38
4
OPERATION
38
GFC 300
www.krohne.com
07/2012 - 4001866001 - AD GFC 300 FF R01 en
VoS_Tolerance
VoS tolerance
R/W
Difference between measured and calculated Vos that will not
generate an VoS alarm (Fct. C1.8.4).
5.0
Settings:
0.0...25.00
Time_Constant_S
time constant
R/W
Time constant to account for in VoS monitor function (Fct.
C1.8.5).
1800.0
Settings:
60.0…3600.0
SENSOR_CAL_
SENSOR_CAL_
SENSOR_CAL_
SENSOR_CAL_
DATE
DATE
DATE
DATE
Sensor Calibration
Date
R
The date of the last sensor calibration.
-
SENSOR_
SENSOR_
SENSOR_
SENSOR_
DIAMETER
DIAMETER
DIAMETER
DIAMETER
meter size
R/W
Pipe diameter of the sensor (Fct. C1.1).
100
Settings:
25.0…1000.0
SENSOR_SN
SENSOR_SN
SENSOR_SN
SENSOR_SN
Sensor Serial
Number
R
The sensor serial number.
-
SENSOR_TYPE
SENSOR_TYPE
SENSOR_TYPE
SENSOR_TYPE
Sensor Type
R
The type of sensor.
Ultrasonic
TRANSDUCER_
TRANSDUCER_
TRANSDUCER_
TRANSDUCER_
DIRECTORY
DIRECTORY
DIRECTORY
DIRECTORY
Transducer
Directory Entry
A directory that specifies the number and starting indices of
the data collections in the transducer block.
0
TRANSDUCER_
TRANSDUCER_
TRANSDUCER_
TRANSDUCER_
TYPE
TYPE
TYPE
TYPE
Transducer Type
R
Identifies the transducer that follows.
Other
V_NO_SENSOR
V_NO_SENSOR
V_NO_SENSOR
V_NO_SENSOR
V no. sensor
R
(Fct. C1.6.6)
-
XD_ERROR
XD_ERROR
XD_ERROR
XD_ERROR
Transducer Error
One of the transducer error codes defined in the FF
Transducer Specifications in section "4.7 Block Alarm
Subcodes".
Uninitialized
Settings:
•
16: Unspecified error
•
17: General error
•
18: Calibration error
•
19: Configuration error
•
20: Electronics Failure
•
21: Mechanical Failure
•
22: I/O Failure
•
23: Data Integrity Error
•
24: Software Error
•
25: Algorithm Error
ZERO_
ZERO_
ZERO_
ZERO_
CALIBRATION
CALIBRATION
CALIBRATION
CALIBRATION
zero calibration
R/W
(Fct. C1.2)
Calib_Action
action
R/W
(Fct. C1.2.1)
no action
Settings:
no action / default / automatic
Calib_Status
status
R
not active / calibration running / calibration OK / calibration
NOK
calibration OK
Calib_Time
runtime
R
Remaining time needed for calibration
0
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value