beautypg.com

Operation – KROHNE GFC 300 FOUNDATION FIELDBUS User Manual

Page 23

background image

OPERATION

4

23

GFC 300

www.krohne.com

07/2012 - 4001866001 - AD GFC 300 FF R01 en

Unacknowledged

R/W

A discrete enumeration which is set to "Unacknowledged"

when an alarm occurs, and set to "Acknowledged" by a write

from a human interface device or other entity which can

acknowledge that the alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized / Acknowledged / Unacknowledged

Alarm State

R

A discrete enumeration which gives an indication of whether

the alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

Time Stamp

R

The time when evaluation of the block was started and a

change in alarm/event state was detected that is unreported.

The time stamp value will be maintained constant until alert

confirmation has been received - even if another change of

state occurs.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Subcode

R

An enumeration specifying the cause of the alert to be

reported.

Other

Setting:

Other / Block Configuration / Link Configuration / Simulation

Active / Local Override / Device Fault State / Device

Maintenance / Input Failure / Output Failure / Memory

Failure / Lost Static Data / Lost NV Data / Readback Check /

Maintenance Needed / Power Up / Out Of Service

Value

R

The value of the associated parameter at the time the alert

was detected.

0

Setting:

0...255

CHANNEL

CHANNEL

CHANNEL

CHANNEL

Channel

Channel

Channel

Channel

R/W

The number of the logical hardware channel that is connected

to this I/O block. This information defines the transducer to be

used going to or from the physical world.

Note:

Note:

Note:

Note:

W = Writeable only by setting "OOS" in MODE_BLK

Uninitialized

Setting:

0 Uninitialized

1 volume flow

2 corr. volume flow

3 mass flow

4 molar mass

5 enthalpy flow

6 spec. enthalpy

7 density

8 flow speed

9 process temperature

10 process pressure

11 electronic temperature

12 velocity of sound

13 gain

14 SNR

15 velocity of sound 1

16 gain 1

17 SNR 1

18 velocity of sound 2

19 gain 2

20 SNR 2

21 velocity of sound 3

22 gain 3

23 SNR 3

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value