beautypg.com

Interface selection – GW Instek PSH-A Series 360W User Manual User Manual

Page 27

background image

Remote

Operation

53

Interface Selection

RS232 (Standard)

Baud rate
setting

1. Press the Menu key

MENU

repeatedly until the

Interface menu appears.

OCP OUT

CV

2.58V

2.01A

Interface RS232
Baud Rate 9600

2. Use the wheel knob

to select the baud

rate.

3. Press the Iset/Vset/Enter key

V

SET

/ I

SET

ENTER

to

confirm the setting.

4. Connect the RS232 cable between your PC

and PSH rear panel. PSH switches to remote

control mode as soon as the connection is
established.

RS-232
interface
protocol

Baud rate: 9600, 4800, 2400, 1200 (selectable)
Parity: None (fixed)

Stop bit: 1 (fixed)
Data bit: 8 (fixed)

PSH RS-232 pin
assignment

1 2 3 4 5

6 7 8 9

Pin 2: RxD
Pin 3: TxD

Pin 5: GND
Pin 1, 4, 6 ~ 9: No Connection

PSH

User

Manual

54

PC RS-232 pin
assignment

1 2 3 4 5

6 7 8 9

Pin 2: TxD

Pin 3: RxD

Pin 5: GND
Pin 1, 4, 6 ~ 9: No Connection

PSH – PC
connection

Null-modem connection, in which transmit (TxD)
and receive (RxD) lines are crosslinked, is
required.

PSH

PC

TxD

RxD

GND

Pin2

Pin3

Pin5

RxD

TxD

GND

Pin2

Pin3

Pin5