OCP (Output Current Protection) Setting

Turn the OCP On/Off

1. Press the Menu key

MENU

repeatedly until the OCP menu
appears.

Set OCP

OFF

OCP OUT

CV

2.58V

2.01A

2. Use the wheel knob

to change

the status to ON (or OFF).

Set OCP

ON

3. Press the Iset/Vset/Enter key

V

SET

/ I

SET

ENTER

to confirm the setting.

Clear OCP error

1. When the output current exceeds

the current setting, the output is

shut off and an OCP error message
appears on the display.

2. Press the Local key

LOCAL

to clear

the error message (the output is

still Off).

OCP Error! Press
“Local” to reset

Range

According to the output current

PSH

User

Manual

50

Display Contrast Setting

Operation

1. Press the Menu key

MENU

repeatedly until the Contrast
menu appears.

OCP OUT

CV

2.58V

2.01A

Set Contrast

71%

2. Use the wheel knob

to change the contrast. Clockwise:

increase, Counterclockwise: decrease.

Range

5% ~ 95%

Step

6%