beautypg.com

Functionality check – GW Instek PSH-A Series 360W User Manual User Manual

Page 17

background image

Setup

33

Remote Sensing Wire Assembly (cont.)

5. Wire shield
connection

To minimize noise effect, we recommend
covering the remote sensing wire with ground
shield and connect it to the ground terminal.

CAUTION

An open remote sense circuit leads to output

level overshoot. Make sure the line is securely
connected.

PSH

User

Manual

34

Functionality Check

Check the PSH basic functionalities before operation.

Preparation

Check items

Output Voltage

OVP functionality

Output Current

OCP functionality

Digital
Multimeter

DC Voltage Accuracy: <±0.1%

Recommended model:

GDM-8245, GDM-8246

Current Shunt

Current range: >100A

Accuracy: <±0.1%

PSH – Current
Shunt cable

Voltage rating: >70V

Current rating: >100A

Equipment

Multimeter –

Current Shunt
cable

N/A

When there is a
problem…

Run calibrations (page61). If this does not solve
the issue, refer to the service center.