beautypg.com

Display – GW Instek PSH-A Series 360W User Manual User Manual

Page 10

background image

PSH

Overview

19

Display

Default
display

Display mode

RMT ADRS OCP OUT

CV

10.10V

36.10A

A

B

C

D

E

F

G

Editing mode

OCP

SET 10.10V

36.10A

A

B

C

D

E

F

G

A

RMT: remote control mode

(Nothing): panel operation mode
Not available in editing mode

B

ADRS: RS-232 or GPIB address (available
in remote control)
Not available in editing mode

C

OCP: Output Current Protection On
(Nothing): Output Current Protection Off

D OUT:

Output

On

(Nothing): Output Off
Not available in editing mode

E

CV/CC: Current and Voltage display
mode (Constant Voltage/ Constant
Current)
SET: Current and Voltage editing mode

F

Output Voltage readback value (display
mode)

Output Voltage setting value (editing
mode)

G

Output Current readback value (display
mode)
Output Current setting value (editing

mode)

PSH

User

Manual

20

Display (cont.)

Menu mode
display

The following displays appear when pressing the
Menu key

MENU

. To move to the next configuration,

press the Menu key repeatedly. When inactive for
more than 5 seconds, the display goes back to the

default mode.

(Default display)

Output Voltage
Protection setting.

For details, see
page48.

Output Current
Protection setting.

For details, see
page49.

Display contrast
setting. For details,
see page50.

Buzzer setting. For
details, see page51.

Set OVP
21.10V

Set OCP
ON (OFF)

Set Contrast

70%

Set Buzzer
ON (OFF)

Interface RS232
Baud Rate 9600

OCP OUT

CV

2.58V

2.01A

Remote control
interface setting. For
details, see page52.