Setup

27

Single PSH + multiple Load

Condition

Output current for each load follows the load
requirement.

When the sum of the load current surpasses the
rating, PSH automatically switches to CC

(Constant Current) mode.

Multiple Loads
+ Local
Sensing

PSH

+OUT

+IN

Load #1

+Sense

Load #2

+IN

—IN

—IN

—OUT

—Sense

All loads share one PSH output.

Multiple Loads
+ Remote
Sensing

PSH

+OUT

+IN

Load #1

+Sense

Load #2

+IN

—IN

—IN

—OUT

—Sense

Distribution

Point

Create a distribution point between PSH and the
loads. PSH compensates the cable loss up to the
distribution point.
To maximize compensation, make sure the
distribution point is closer to the load side.

PSH

User

Manual

28

Multiple PSH + single load (series operation)

Condition

Up to four PSH series (with identical output
ratings) can be cascaded.

Output voltage is the sum of the cascaded PSH.

Output current is the same as a single PSH.

Series
Operation +
Local Sensing

PSH #1

+OUT

+IN

Load

+Sense

PSH #2

+OUT

+Sense

—IN

—OUT

—OUT

—Sense

—Sense

First PSH:
Negative output → Negative load input
Positive output → The next PSH negative output

Intermediate PSH:
Negative output → The previous PSH positive
output
Positive output → The next PSH negative output

Last PSH:
Negative output → The previous PSH positive
output
Positive output → Positive load input