Setup

29

Series Operation (cont.)

Series
Operation +
Remote
Sensing

PSH #1

+OUT

+IN

Load

+Sense

PSH #2

+OUT

+Sense

—IN

—OUT

—OUT

—Sense

—Sense

First PSH:
Negative output → Negative load input
Positive output → The next PSH negative output
Negative sense → Negative load input
Positive sense → Positive output monitor

Intermediate PSH:
Negative output → The previous PSH positive
output
Positive output → The next PSH negative output
Negative sense → The previous PSH positive
output
Positive sense → Positive output monitor

Last PSH:
Negative output → The previous PSH positive
output
Positive output → Positive load input
Negative sense → The previous PSH positive
output
Positive sense → Positive load input

PSH

User

Manual

30

Load Wire Assembly

1. Wire
selection

Select the appropriate wire according to the

guideline on page25.

2. Terminal
screw
replacement

Replace the two screws on the output terminal
with the hex screw in the output connection kit.

3. Terminal
connection

Screw load wires to the terminal.