beautypg.com

Output voltage setting – GW Instek PSH-A Series 360W User Manual User Manual

Page 23

background image

Panel

Operation

45

Constant Voltage/ Constant Current

Crossover Characteristic

PSH series automatically switch

between constant voltage mode
and constant current mode,
according to the load change.

When the load current is
smaller
than the limit (I

SET

),

PSH operates in Constant
Voltage mode
, changing the

current level according to the
load but keeping the Voltage
level at the limit (V

SET

).

When the load current is the

same as the limit (I

SET

), PSH

operates in Constant Current
mode
, changing the Voltage level

according to the load but
keeping the Current level at the

limit (I

SET

).

V

SET

I

SET

Constant

Voltage

Constant

Current

V

I

V

SET

= Output Voltage setting

I

SET

= Output Current setting

Let’s take recharging a 12V battery as an example. PSH output

setting is 13.8V, 1A. An empty battery puts a heavy current load
on the power supply. PSH starts running at Constant Current
mode, supplying full 1A current but keeping the voltage lower

than 13.8V. As the battery becomes charged, the load also
becomes smaller. PSH then switches to Constant Voltage mode,
supplying less than 1A current but supplying full 13.8V.

Display

The display indicates CV (Constant Voltage) or CC
(Constant Current) on the left side.

Constant Voltage

OCP OUT

CV

2.58V

1.99A

Constant Current

OUT

CC

1.33V

2.00A


PSH

User

Manual

46

Output Voltage Setting

Operation

1. Press the Vset/ Iset key

V

SET

/ I

SET

repeatedly to move the underline
to the Voltage side.

OCP

SET

2.58V

2.01A

2. Press the F/C key

F/C

to move the

underline before or after the

decimal point.

OCP

SET

2.58V

2.01A

3. Use the wheel knob

to change the output voltage.

Range

0.00V ~ rating voltage

Step

10mV (rating voltage < 36V)