beautypg.com

SilentKnight VisorAlarm ARLY Interface User Manual

Page 84

background image

VISOR ALARM – ARLY Monitoring

IV - 79

Doc.DM359-I

Rev.2.0

Syntax:

ARLY-1+CLEAR ALARM INFORMATION

Example:

ARLY-1+CLEAR ALARM INFORMATION
Are you sure ?(Yes/No) [No]? y
ARLY-1+

CLEAR ALARM STATISTICS

Deletes statistics supported by the VisorALARM relative to sent and received alarms. These statistics
can be viewed through the monitoring command LIST ALARM STATISTICS.
Syntax:

ARLY-1+CLEAR ALARM STATISTICS

Example:

ARLY-1+CLEAR ALARM STATISTICS
ARLY-1+

b) CLEAR INTERFACE-STATISTICS
Deletes statistics relative to the transmitting and receiving of data through the serial interface. These
statistics can be viewed through the monitoring command LIST INTERFACE-STATISTICS.
Syntax:

ARLY-1+CLEAR INTERFACE-STATISTICS

Example:

ARLY-1+CLEAR INTERFACE-STATISTICS
ARLY-1+

c) CLEAR PROTOCOL
Deletes statistics relative to the transmitting and receiving of data through the configured UDP port for
the ARLY interface. This also deletes statistics relative to the protocol used to communicate the MIPs
and the VisorALARM. These statistics can be viewed through the LIST UDP-STATISTICS and
LIST PROTOCOL commands.
Syntax:

ARLY-1+CLEAR PROTOCOL

Example:

ARLY-1+CLEAR PROTOCOL
ARLY-1+

d) CLEAR VISORALARM-STATE
Deletes the last date when configuration synchronization was produced and in the case of a backup
VisorALARM, this also deletes the period of time the device has been in BACKUP state.
Syntax:

SEPI-serial0/1+CLEAR VISORALARM-STATE

Example:

SEPI-serial0/1+CLEAR VISORALARM-STATE
SEPI-serial0/1+