SilentKnight VisorAlarm ARLY Interface User Manual
Page 84

VISOR ALARM – ARLY Monitoring
IV - 79
Doc.DM359-I
Rev.2.0
Syntax:
ARLY-1+CLEAR ALARM INFORMATION
Example:
ARLY-1+CLEAR ALARM INFORMATION
Are you sure ?(Yes/No) [No]? y
ARLY-1+
•
CLEAR ALARM STATISTICS
Deletes statistics supported by the VisorALARM relative to sent and received alarms. These statistics
can be viewed through the monitoring command LIST ALARM STATISTICS.
Syntax:
ARLY-1+CLEAR ALARM STATISTICS
Example:
ARLY-1+CLEAR ALARM STATISTICS
ARLY-1+
b) CLEAR INTERFACE-STATISTICS
Deletes statistics relative to the transmitting and receiving of data through the serial interface. These
statistics can be viewed through the monitoring command LIST INTERFACE-STATISTICS.
Syntax:
ARLY-1+CLEAR INTERFACE-STATISTICS
Example:
ARLY-1+CLEAR INTERFACE-STATISTICS
ARLY-1+
c) CLEAR PROTOCOL
Deletes statistics relative to the transmitting and receiving of data through the configured UDP port for
the ARLY interface. This also deletes statistics relative to the protocol used to communicate the MIPs
and the VisorALARM. These statistics can be viewed through the LIST UDP-STATISTICS and
LIST PROTOCOL commands.
Syntax:
ARLY-1+CLEAR PROTOCOL
Example:
ARLY-1+CLEAR PROTOCOL
ARLY-1+
d) CLEAR VISORALARM-STATE
Deletes the last date when configuration synchronization was produced and in the case of a backup
VisorALARM, this also deletes the period of time the device has been in BACKUP state.
Syntax:
SEPI-serial0/1+CLEAR VISORALARM-STATE
Example:
SEPI-serial0/1+CLEAR VISORALARM-STATE
SEPI-serial0/1+