SilentKnight VisorAlarm ARLY Interface User Manual
Page 37

VISOR ALARM – ARLY Configuration
II - 32
Doc.DM359-I
Rev.2.0
ARLY-1 Cfg>list mip 9997
Account number : 9997
Serial number : 8209/00270
Alarm Receiver IP address : 81.23.69.152
Backup Alarm Receiver IP address : 81.23.70.54
Maintenance Receiver IP address : 81.23.56.89
Maintenance Alarm Password : 2AB4
Alarm Receiver UDP Port : 1222
MIP Console Password : 1111
MIP Password : 220771B
Alarm Receiver Password : 220771B
Keep-alives.
Timer : 21
Retries : 3
Retries Timer : 5
Backup Receiver Keep-alives.
Timer : 15
Retries : 4
Retries Timer : 1
Alarm Transmission Retries : 2
Telephone Number Length : 9
Callback Telephone Number :
Zone ID for local events : 015
ARLY-1 Cfg>
h) LIST PRIORITY-STANDARD
Lists the priority standard configured at the VisorALARM receiver.
Syntax:
ARLY-1 Cfg>list priority-standard
Example:
ARLY-1 Cfg>list priority-standard
Priority:
--------
Priority Standard : UL (US)
i) LIST SERIAL-PARAMETERS
Lists the serial line configuration parameters for the serial line over which the events are sent
to the automation software.
- 5104 Digital Alarm Communicator Transmitter 6 Zone (48 pages)
- 5128 Digital Alarm Communicator Transmitter (42 pages)
- 5217 10-Zone Expander for 5208 (2 pages)
- 5220 Direct Connect Module (2 pages)
- 5235 Remote Annunciator for 5208 (2 pages)
- 5280 Status Display Module for 5208 (2 pages)
- 5495 6A Distributed Power Module (52 pages)
- 5496 6A Intelligent Remote Power Supply (38 pages)
- 5499 9A Distributed Power Module (56 pages)
- 5600 (114 pages)
- 5660 Silent Knight Software Suite (28 pages)
- 5670 IntelliKnight Facility Management Software (24 pages)
- 5700 (180 pages)
- 5808 (180 pages)
- 5815RMK Remote Mounting Kit (2 pages)
- 5815XL Signal Circuit Expander (2 pages)
- 5820XL-EVS (236 pages)
- 5824 Serial/Parallel Module (2 pages)
- 5860/5860R Remote Annunciator (2 pages)
- 5865-3/5865-4 Remote LED Annunciator (2 pages)
- 5880 LED Driver Module (2 pages)
- 5883 Relay Interface Board (4 pages)
- 5895XL 6A Intelligent Remote Power Supply (56 pages)
- B200S Intelligent Sounder Base with CO Support (4 pages)
- B200S-LF - Low Frequency Intelligent Sounder Base (4 pages)
- B200SR Sounder Base (4 pages)
- B200SR-LF Low Frequency Intelligent Sounder Base (4 pages)
- B210LP 6 Mounting Base (2 pages)
- B224BI 6 Mounting Base w/Built-in Isolator (2 pages)
- B224RB 6 Mounting Base w/Built-in Relay (4 pages)
- B501 4 Mounting Base (2 pages)
- Central Station Monitoring List (1 page)
- Document Revision History (4 pages)
- EVS (74 pages)
- EVS-CE4 (2 pages)
- EVS-RVM (2 pages)
- EVS-VCM (2 pages)
- FFT (1 page)
- FFT-24 (2 pages)
- FFT-24 Installation (1 page)
- FFT-FPJ (1 page)
- FFT-HSC (1 page)
- FFT-STSS and FFT-STSR (2 pages)
- HFS-D (4 pages)
- HFS-MM (1 page)