Example:

ARLY-1 Cfg>MIP 101234 BCK-KEEP-ALIVE-RETRIES 30
ARLY-1 Cfg>


To return to the default configuration for this parameter, use the following command.

ARLY-1 Cfg>NO MIP accnt BCK-KEEP-ALIVE-RETRIES num_times

p) MIP accnt BCK-KEEP-ALIVE-RETRIES-TIMER
This parameter is the same as the keep-alive-retries-timer however it is applied to the
backup VisorALARM.

Syntax:

ARLY-1 Cfg>MIP accnt BCK-KEEP-ALIVE-RETRIES-TIMER time

time

Time in seconds between keep-alive frames when a possible
connectivity failure has been detected. Admits values between 3 and
9.


Example:

ARLY-1 Cfg>MIP 101234 BCK-KEEP-ALIVE-RETRIES-TIMER 3
ARLY-1 Cfg

>


To return to the default configuration for this parameter, use the following command.

ARLY-1 Cfg>NO MIP accnt BCK-KEEP-ALIVE-RETRIES-TIMER time

q) MIP accnt RESET
This command does not handle configuration but restarts the mIP/IPDACT with account accnt.
Syntax:

ARLY-1 Cfg>MIP accnt RESET


Example:

ARLY-1 Cfg>MIP 101234 RESET
ARLY-1 Cfg>

r) MIP accnt LOCAL-EVENTS-ZONE
This parameter defines the base number for the zone field that will be appear in all the events
generated by a mIP/IPDACT that does not come from the Alarm Panel. This parameter is not sent to
the mIP/IPDACT when a register is produced, rather it is stored in the mIP/IPDACT local
configuration and is used for local events generated for this account number.
Syntax:

ARLY-1 Cfg> MIP accnt local-events-zone identifier-zone

identifier-zone

This is a hexadecimal number of up to three digits.


Example: