SilentKnight VisorAlarm ARLY Interface User Manual
Page 21

VISOR ALARM – ARLY Configuration
II - 16
Doc.DM359-I
Rev.2.0
checked first. The range is from 1 to 255.
Example:
ARLY-1 Cfg>CFG-PATTERN 10 DEFAULT
ARLY-1 Cfg>
b) CFG-PATTERN n INSTALATOR-PASSWORD
Configures the installer password which permits access to this pattern. Only the encrypted register
petitions with this password can use this pattern.
Syntax:
ARLY-1 Cfg>CFG-PATTERN n INSTALATOR-PASSWORD password
password
Password of up to 16 hexadecimal digits (0 to 9, A, B, C, D, E and F).
Example:
ARLY-1 Cfg>CFG-PATTERN 10 INSTALATOR-PASSWORD 1234FBAA
ARLY-1 Cfg>
To return this parameter to the default configuration, use the following command:
ARLY-1 Cfg>NO CFG-PATTERN n INSTALATOR-PASSWORD password
c) CFG-PATTERN n AUTOMATION-INSTALATION-PASSWORD
This lets you to generate automatically a keyword for CESAR ciphering (this is valid only for mIP
devices up to 2.2 release) for the mIP installacion process. This is the keyword that must be supplied
to the mIP device for the registration process. This installation keyword specify the parameter set that
the receiver submits to the mIP device in the registration.
d) CFG-PATTERN n RECEIVER-IP
Configures the alarm receiver IP address in the MIP.
Syntax:
ARLY-1 Cfg>CFG-PATTERN n RECEIVER-IP ip_address
ip_address
Alarm receiver IP address.
Example:
ARLY-1 Cfg>CFG-PATTERN 10 RECEIVER-IP 172.24.78.99
ARLY-1 Cfg>
To return to the default configuration for this parameter, use the following command:
ARLY-1 Cfg>NO CFG-PATTERN n RECEIVER-IP ip_address
e) CFG-PATTERN n RECEIVER-UDP-PORT
Configures the UDP port for connection with the various mIP/IPDACTs.
Syntax:
ARLY-1 Cfg>CFG-PATTERN n RECEIVER-UDP-PORT port_number