beautypg.com

Install chemical anchors bolt plinth to floor – Triton 8100 User/Installation Manual User Manual

Page 135

background image

A-23

I

NSTALLATION

P

ROCEDURES

Install Chemical Anchors

Bolt Plinth to Floor

1.

Move the plinth into position for mounting by aligning the base over the
four holes drilled in the previous procedure.

2.

Begin by inserting a Chem Stud capsule into one of the mounting holes.
Either end of the capsule may be inserted first.

3.

Place a washer and a nut (in that order) onto a chisel point rod. Thread the
nut onto the rod, leaving 3 to 4 threads exposed.

4.

Thread the rod coupler onto the threaded rod until it is tight against the nut.
The threaded rod used should be free of dirt, grease, oil or other foreign
material.

5.

Select the drive unit, insert it into a rotary hammer drill and engage the
coupling to be used.

Insert Chem Stud capsule in

mounting hole.

Prepare chisel point anchor rod. Add

washer and nut.

6.

Insert the chisel point of the rod
into the hole to break the glass
capsule. Spin it into the capsule at
a speed of 250 to 500 RPM, until
it is fully embedded.
IMPORTANT! Turn the rotary
hammer drill OFF
IMMEDIATELY when the rod is
fully embedded!

Drive anchor rod into capsule using

hammer drill.