beautypg.com

E_port default port health monitoring thresholds – Brocade Monitoring and Alerting Policy Suite Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 103

background image

Default Port Health monitoring thresholds for D_Ports (Conservative Policy) (Continued)

TABLE 27

Monitoring statistic

Unit

Threshold

Actions

Sync Loss
(defALL_D_PORTSLOSS_SYNC_H90)

Hour

90

EMAIL, SNMP, RASLOG

CRC Errors (defALL_D_PORTSCRC_D1500)

Day

1500

EMAIL, SNMP, RASLOG

Protocol Errors (defALL_D_PORTSPE_D1500)

Day

1500

EMAIL, SNMP, RASLOG

Invalid Transmit Words
(defALL_D_PORTSITW_D1500)

Day

1500

EMAIL, SNMP, RASLOG

Link Failure (defALL_D_PORTSLF_D1500)

Day

1500

EMAIL, SNMP, RASLOG

Sync Loss
(defALL_D_PORTSLOSS_SYNC_D1500)

Day

1500

EMAIL, SNMP, RASLOG

E_Port default Port Health monitoring thresholds

The following table lists the default Port Health monitoring thresholds for E_Ports.

Default Port Health monitoring thresholds for E_Ports

TABLE 28

Monitoring statistic

MAPS E_Port high/low thresholds and actions per policy

Aggressive

Moderate

Conservative

Actions

C3 Time out
(C3TX_TO)

5

10

20

EMAIL, SNMP, RASLOG

CRC Errors (CRC)

0/2

10/20

21/40

Low threshold: EMAIL, SNMP, RASLOG

High threshold: EMAIL, SNMP, FENCE,
DECOM

Invalid Transmit Words
(ITW)

15/20

21/40

41/80

Low threshold: EMAIL, SNMP, RASLOG

High threshold: EMAIL, SNMP, FENCE,
DECOM

Link Reset (LR)

2/4

5/10

11/20

Low threshold: EMAIL, SNMP, RASLOG

High threshold: EMAIL, SNMP, FENCE,
DECOM

State Change
(STATE_CHG)

2/4

5/10

11/20

Low threshold: EMAIL, SNMP, RASLOG

High threshold: EMAIL, SNMP, FENCE,
DECOM

Protocol Errors (PE)

0/2

3/7

5/10

Low threshold: EMAIL, SNMP, RASLOG

High threshold: EMAIL, SNMP, FENCE,
DECOM

MAPS Threshold Values

Monitoring and Alerting Policy Suite Administrator's Guide

103