Power Amp DC
Output Alert (per
ch.)
The output DC value of a given amplifier
channel is greater than 10V.
Power Amp
Overtemperature
(per ch.)
Over-temperature value of the power
amplifier (no over-temperature, >70°C and
reducing output by 3dB, >80°C and
reducing by 6dB), >90° and muting
output).
Peak Limiter (per
ch.)
The peak limiter is working to protect the
amplifier for the channel.
Orange LED (Network
and Control tabs)
Protection (per ch.) Speaker protection (displacement or
thermal)
Orange LED (Network
and Control tabs)
Amp protect
Protection status of the amplifier. If
protecting, it is reducing or muting one or
several outputs due to malfunctions as
overheating, output DC, short circuitry…
See the user manual for more details about
the meaning of combinations of LEDs
indicator and LCD display.
Orange LEDs (Network
and Control tabs)
Sense (per ch.)
A certain level of current is detected on the
output (a cabinet is connected and some
sufficient signal is flowing to it).