SM 04P02B01-01E
Replacing Parts
7
5.
Remove the latch from the Holder Lock on the right panel, then slide it to the left
side and remove the Holder Lock.
Holder Lock
Latch
Latch
6.
Pull the Ribbon Holder Assembly toward you and remove.
7.
Disconnect the Band that holds the cables in place. Remove the two latches
securing the Ribbon Feed Motor, then turn clockwise and remove the Ribbon
Feed Motor.
Latch
Latch
Ribbon Feed Motor
Band
8.
Release the latch securing the Ribbon Feed Gear, then remove the Ribbon
Feed Gear.
Latch
Ribbon Feed Gear
7.5 Disassembly Procedure (Dot Model)
This manual is related to the following products:
See also other documents in the category Yokogawa Sensors:
- EJA120A (47 pages)
- EJA120A (79 pages)
- EJA130A (2 pages)
- EJA130A (4 pages)
- EJA120A (31 pages)
- EJA130A (47 pages)
- EJA120A (40 pages)
- EJA438 (5 pages)
- EJA120A (6 pages)
- EJA115 (85 pages)
- EJA210A (70 pages)
- EJA130A (4 pages)
- EJA430A (78 pages)
- EJA210E (52 pages)
- EJA210E (89 pages)
- EJA210E (170 pages)
- EJX120A (4 pages)
- EJA210E (9 pages)
- EJX115A (55 pages)
- EJA210E (41 pages)
- EJA210E (96 pages)
- EJX910A (9 pages)
- EJX910A (103 pages)
- FlowNavigator Software (163 pages)
- EJX910A (55 pages)
- EJX910A (175 pages)
- EJX910A (83 pages)
- EJA530A (67 pages)
- EJA120A (83 pages)
- EJX530A (52 pages)
- EJA110E (4 pages)
- EJA110E (85 pages)
- EJX120A (85 pages)
- EJA118 (76 pages)
- EJX118A (64 pages)
- EJA438 (72 pages)
- EJA430E (85 pages)
- EJX430A (6 pages)
- EJX430A (40 pages)
- EJX430A (76 pages)
- EJA430E (7 pages)
- EJA430E (41 pages)
- EJA430E (96 pages)
- EJX438A (10 pages)
- ADMAG AXR (194 pages)