A1.4 DI Function Block

TA0104-1.ai

AUTO

Relative

Index

Index

Parameter Name

Factory Default

Write

Mode

Explanation

AUTO

AUTO

AUTO

Block Tag

= O/S

AUTO

6000

6001

6002

6003

6004

6005

6006
6007

6008
6009

6010
6011
6012

6013
6014

6015

6016
6017

6018

6019
6020
6021

6022
6023
6024

0

1

2

3

4

5

6
7

8
9

10
11
12

13
14

15

16
17

18

19
20
21

22
23
24

0 s

Disabled

0

0

AUTO

Block Header

ST_REV

0

SIMULATE_D

TAG_DESC

STRATEGY

ALERT_KEY

MODE_BLK

BLOCK_ERR

PV_D

OUT_D

XD_STATE
OUT_STATE
GRANT_DENY

IO_OPTS

STATUS_OPTS

0

1

O/S

(spaces)

1

CHANNEL

PV_FTIME

0

4 (DI1)

5 (DI2)

0xffff (Unack)

AUTO

MAN

DI1 DI2

6100

6101

6102

6103

6104

6105

6106
6107

6108
6109

6110
6111
6112

6113
6114

6115

6116
6117

6118

6119
6120
6121

6122
6123
6124

0

O/S

Information on this block such as the block tag, DD

revision, and execution time
The revision level of the static data of the DI block. The

value of this parameter is incremented each time a static

parameter value is changed.

The user description of the intended application of the

block
Used by an upper-level system to identify grouping of the

block. Not checked or processed by the block.
The identification number of the plant unit. This

information may be used in the host for sorting alarms.

The actual, target, permitted, and normal modes of the

block

Indicates the error statuses related to the block itself.
The primary discrete value (or process value) for

execution of the block’s functions.

Indicates the value and status of block’s output.

Allows use of values manually set instead of the limit

switch input from the transducer block. When Disable is

set for this value, the block reflects the actual input value

and status. 1 = Disabled, 2 = Active
Not used in a AV550G.
Not used in a AV550G.

Option to control access from the host computer and local

control panel to tuning and alarm parameters. Before

write access to a parameter, set the GRANT bit in this

parameter to have the operation right to be granted. Then

after write access, check the DENY bit in this parameter.

If the write access is complete successfully, it is not ON.
Sets the block input/output options.
Defines block actions depending on block status

conditions. For DI blocks of a AV550G, only bit 0 (Invert:

on/off state inversion) is effective.

The channel number of the transducer block’s logical

hardware channel connected to this block. This parameter

is always fixed for the DI block of the AV550G.

Sets the time constant of damping for PV_D.

The status of the limit switch signal transferred from the

transducer block
Shows the contents of an update event (a change to the

setpoint) upon occurrence.

Shows the contents of a block alarm upon occurrence.

Indicates the current alarm statuses.

Selects whether alarms associated with the block will be

automatically acknowledged.
Sets the alarm priority level.
Indicates the status of the input for the discrete alarm.
Indicates the status related to the discrete alarm.

FIELD_VAL_D

UPDATE_EVT

BLOCK_ALM

ALARM_SUM
ACK_OPTION

DISC_PRI

DISC_LIM

DISC_ALM

0

0

O/S

O/S

AUTO

AUTO

AUTO

AUTO

0