Warning – Proface LT4300M - 5.7 Modular HMI + Control" User Manual
Page 21
LT-4201TM/4301TM Hardware Manual
21
Interfaces are: COM1, Ethernet, USB1 and USB2.
KC Markings
WARNING
RISK OF EXPLOSION IN HAZARDOUS LOCATIONS
Verify that the power, input, and output (I/O) wiring are in accordance with Class I, Division 2
wiring methods.
Do not substitute components that may impair compliance to Class I, Division 2.
Do not connect or disconnect equipment unless power has been switched off or the area is
known to be non-hazardous.
Securely lock externally connected units and each interface before turning on the power
supply.
Do not, connect, or disconnect USB cable unless area is known to be non-hazardous.
Potential electrostatic charging hazard: wipe the front panel of the terminal with a damp cloth
before turning ON.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
WARNING
RISK OF EXPLOSION IN HAZARDOUS LOCATIONS
Do not disconnect while circuit is live.
Potential electrostatic charging hazard: wipe the front panel of the terminal with a damp cloth
before turning ON.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.