Canbus trigger, decode, and measure – Teledyne LeCroy CANbus TD and CANbus TDM - Operators Manual User Manual
Page 60
![background image](/manuals/353658/60/background.png)
CANbus Trigger, Decode, and Measure
60
CANbus-TD-TDM-OM-E RevB
Cable Set Part Number 902329-00
Quantity
Description
1
0.3 m cable with 9-pin DSUB socket connectors on each
end, and with pins 2 and 7 connected, including 120 ohm
terminations on each end.
1
2 m cable with 9-pin DSUB socket connectors on each end,
and with pins 2, 3 and 7 connected (but without 120 ohm
terminations). One end has a “Y” connection for parallel
connection of multiple nodes.
1
0.5 m cable with 9-pin DSUB socket connector on one end,
and wires for pins 2, 3, and 7. No 120 ohm terminations.
2
CAN adapter with one 9-pin DSUB plug connector and one
9-pin DSUB socket connector with all pins connected.
Includes 120 ohm termination between pins 2 and 7.
Note: This cable set is ideal for high-speed CAN. (ISO 11898-2)
Cable Set Part Number 902330-00
Quantity
Description
1
0.3 m cable with 9-pin DSUB socket connectors on each
end, and with pins 2, 3 and 7 connected.
1
2 m cable with 9-pin DSUB socket connectors on each end,
and with pins 2, 3, and 7 connected (but without 120 ohm
terminations). One end has a “Y” connection for parallel
connection of multiple nodes.
1
0.5 m cable with 9-pin DSUB socket connector on one end,
and wires for pins 2, 3, and 7. No 120 ohm terminations.
Note: This cable set is ideal for low-speed CAN. (ISO 11898-3, ISO 11519, SAE J2411)