CANbus Trigger, Decode, and Measure

46

CANbus-TD-TDM-OM-E RevB

Trigger Capability

CANbus TD and TDM

# Data Bytes = 0 to 8. Data can be defined by nibble. Triggers on that

data pattern regardless of position.

Binary:

Any combination of 0,1, or X for 1-64 bits. Triggers on that data pattern

regardless of position.

Bit Rates

10, 25, 33.333, 50, 83.333, 100, 125, 250, 500, 1000 kb/s or user-defined

between 10-1000 kb/s.

Trigger Input

Any analog Channel or the EXT input.

Trigger Design

Internal to oscilloscope, settable like any other oscilloscope trigger.

Search Capability

CANbus TD and TDM

Search Options

Search for Any Frame, Any Error or Frame ID in Hexadecimal format.

Measure and Graph
Capability

CANbus TD

CANbus TDM

CAN Timing
Measurements

Not Applicable

CAN-CAN, CAN-Analog, Time@CAN,

CAN Message Bitrate.

CAN Data Extraction

Not Applicable

CAN-Value.

CAN Bus Load
Measurements

Not Applicable

CAN Bus Load %.

Graphing Functions

Not Applicable

Track, Trend and Histogram of CAN

measurements.