16-5. Global
variables
The descriptions of global variables and global strings are displayed. In addition, numeric values
can be assigned to global variables while character strings can be assigned to global strings.
Select the F4 (GVar) key on the Moni screen.
Mode flow:
Global variables are displayed with the following 3
types:
Itg:
Integer (No. 200 - 299, No. 1200 - 1299)
Real: Real number (No. 300 - 399, No. 1300 - 1399)
Str:
String (No. 300 - 999)
(1) Global integer variables
Mode flow:
(2) Global real variables
Mode flow:
The cursor is located at the data (variable description). Entering a numeric value with the ten-key
numeric pad and pressing the return key can assign the numeric value to the variable. Move the
cursor with the return key or the ← key.
The variable Nos. can be changed with the PAGE UP and PAGE DOWN keys.
(3) Global strings
Mode flow:
The cursor is located at the data (column).
Entering an ASCII code with the ten-key numeric
pad and pressing the return key can assign the
characters.
(A to F of hexadecimal notation can be input by
changing Num to Alph with the F1 (Alph/Num) key.
Move the cursor with the return key or ← key.
The PAGE UP and PAGE DOWN keys display the
column Nos. by shifting the numbers by 20.
114