beautypg.com

Remote totalizer menu, Pd counter – Ronan X96S MASS FLOW GAUGE User Manual

Page 27

background image

23

Remote Totalizer Menu

The Remote Totalizer menu is used to configure the parameters associated with the Remote Totalizer. It contains the following
items:

ITEM

FUNCTION

Units per Pulse

Shows and allows the user to set the number of units per pulse for the Remote
Totalizer.

Remote Tot Units

Shows and allows the user to set the units to be used for the Remote Totalizer.

Min Period

Shows and allows the user to set the minimum pulse period.

Remote Totalizer Units is one of the following:

ITEM

MEANING

Ston

short tons

Lton

long tons

Lb

Pounds

ounce

Ounces

MetTon

metric tons

kg

kilograms

g

grams

PD Counter

The PD Counter menu is used to configure the parameters associated with the Pre-Determined Counter. It contains the following
items:

ITEM

FUNCTION

PD Count

Shows the accumulated mass flow in the Pre-Determine Count register

PD Limit

Shows and allows the user to set the limit for the PD Counter.

PD Units

Shows and allows the user to set the units to be used for the PD Counter.

Reset PD Cntr

Shows and allows the user to reset the PD Counter locally