Special commands, Serial commands (cont’d), 11 communications – Electro Cam PS-6144 Series User Manual
Page 83

6-11 Communications
Special
Commands
CMD
(hex)
Name
Function
2A
Key Press
Adds a value to the keyboard buffer; just like pressing a key.
Cmd:
! ADR 2A XX CSM
Reply:
A
where “XX” is the key number in hex. See “Keypad Diagnostics”
in Section 7 for a method to determine the key number for each
key on the keypad.
2B
En Mot Spt
Enable “Motion ANDing” programming at operator level.
Put:
! ADR 2B P <00 or 01> CSM
Reply:
A
Get:
! ADR 2B G CSM
Reply:
A <00 or 01> CSM
where “00” = disabled, “01” = enabled.
2C
En Offset
Enable “Offset” programming at operator level.
Put:
! ADR 2C P <00 or 01> CSM
Reply:
A
Get:
! ADR 2C G CSM
Reply:
A <00 or 01> CSM
where “00” = disabled, “01” = enabled.
2D
En Act Pgm
“Active Program” enable at operator level.
Put:
! ADR 2D P <00 or 01> CSM
Reply:
A
Get:
! ADR 2D G CSM
Reply:
A <00 or 01> CSM
where “00” = disabled, “01” = enabled.
2E
En Spd Cmp
Enable “Speed Comp” programming at operator level.
Put:
ADR 2E P XX <00 or 01> CSM
Reply:
A
Get:
! ADR 2E G XX CSM
Reply:
A <00 or 01> CSM
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
2F
En Timed Out
Enable “Timed Output” programming at operator level.
Put:
! ADR 2F P XX <00 or 01> CSM
Reply:
A
Get:
! ADR 2F G XX CSM
Reply:
A <00 or 01> CSM
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
Serial Commands (cont’d)