3-19 Programming
Output Groups (Cont’d)
Grouping Example 3—Three Groups
Output
Includes
Group
Outputs
Mode
1
1 & 2
0
2
3 & 4
4
3
5 thru 25
0
Programming
Begin by moving the cursor to GRP QTY and entering the number of groups desired,
followed by ENT.
Next, move the cursor to GRP and enter “1” followed by ENT.
Move the cursor to CHNS and enter the number of output channels to be included in
Group 1, followed by ENT.
Move the cursor to MODE and enter the operating mode for the group from zero to five,
followed by ENT. See Section 5 for an explanation of the operating characteristics of
each mode.
Move the cursor back to GRP and repeat these steps for each group to be programmed.
Main Screen
When output channels are divided into groups, the appearance of the Main Screen will
change slightly. See MAIN SCREEN for details.
See Also
MAIN SCREEN
OFFSET
GRP POS DISP
Output Status
Menu Path
MAIN SCREEN
to SETUP MENU
to I/O STATUS
to OUTPUT STATUS
Purpose
This screen shows the On/Off state of the output channels, and it allows the outputs to
be forced.
Screens
If any output positions have been programmed as analog outputs, the On/Off status will
show “A” instead of “0” or “1.”
12345678 OUTPUT
01001001 1-8<
Output On/Off Status (O=Off, 1=On)
Output Numbers (1-8)
Both Models, Outputs 1-8
901234567 OUTPUT
0100100AA 9-17<
Analog Modules shown with "A"
Output Numbers (9-17)
PS-6344-17, Outputs 9-17
90123456 OUTPUT
01001000 9-16<
Output Numbers (9-16)
PS-6344-25, Outputs 9-25
789012345 OUTPUT
0100100AA 17-25<
Analog Modules shown with "A"
Output Numbers (17-25)