Electrical

Input Power

20-30 VDC. Keypad/display is powered from controller.

Input Current

500 mA maximum (control only)

Power Consumption:

35 W

Permanent Memory:

EEPROM (no battery required)

Accessory Power Out:

20-30 VDC, 250 mA Max (same source and voltage as input power)

Environment

Operating Temp:

0

°

to 55

°

C (32

°

to 131

°

F)

Storage Temp:

-40

°

to 70

°

C (-40

°

to 160

°

F)

Humidity:

95% maximum relative non-condensing

NEMA Rating:

Keypad/Display: NEMA 4

Physical

Overall Dimensions:

See Figure 4

Weight:

Controller: 3.5 lbs (1.6 kg). Keypad/Display: 0.5 lbs. (0.2 kg)

Mounting

Controller:

Brackets accept EN-50035 (“G” profile) or EN-50022 (“Top Hat” profile) DIN rail.

Keypad/Display:

Mounts up to 1000' from controller. Multiple keypads may be connected to one controller.

Inputs

DC Inputs:

16 sinking or sourcing DC inputs, optically isolated.

Input ON State Voltage:

10-30 VDC

Input Current:

11 mA @ 24 VDC

Program Select Response:

100 ms typical; may be longer with large numbers of setpoints.

Response of All Other Inputs:

1-2 scans

Outputs: PS-6144-24-(P16 or N16)M09

Real World Outputs:

Up to nine Slimline modules may be mounted on controller. Modules may be any mix of AC,

DC, reed relay, and up to two analog. All modules optically isolated.

DC (Transistor) Outputs:

16 sinking (N16) or sourcing (P16), optically isolated. Sinking or sourcing must be specified on

order.

Outputs: PS-6144-24-M17

Real World Outputs:

Up to 17 Slimline modules may be mounted on controller. Modules may be any mix of AC, DC,

reed relay, and up to two analog. All modules optically isolated.

Analog Output

Output Types:

4-20 mA or 0-10 VDC, proportional to RPM.

Resolution:

12 bit

Update Frequency:

10 times/sec minimum

Linearity:

±

0.3% of full scale @ 25

°

C (77

°

F)

Set-up:

Offset and full scale RPM are programmable.

Operation

Scan Time:

300-500 ms (exact time determined by programming)
For higher speeds, interrupt-driven versions available—consult factory.

Position Resolution:

10 bits (1024 increments). 12 bits (4096 increments) available with “-H” option.

Speed Compensation:

Programmed in 0.1 msec steps. 16 individually compensated outputs max. Updated ten times

per second. Separate leading/trailing edge compensation available with option “-L” (update time
typically five times per second).

Output Timeout:

1.0 ms time base (accuracy: +1, -0 ms)

Number of Timed Outputs:

Four maximum

Multiple Programs:

48 programs standard (256 available with “-F” Option)

Total Pulse Memory:

1258 pulses standard (4589 available with “-F” Option)

Pulses per Program:

512 maximum standard (512 available with “-F” Option)

Pulses per Output:

512 maximum standard (512 available with “-F” Option)

Maximum Speed:

3000 RPM

RS-232 Serial Communication

Port Types:

1 RS-282 or 1 RS-422/485—R-485 can be configured as a “Multi-Drop” network.

Baud Rates: