CMD
(hex)
Name
Function
28
Inc Spt
Advances one edge of a pulse, both edges, or all pulses in a
channel, by one scale factor increment.
Cmd:
! ADR 28 XX YY ZZZZ TTTT MM CSM
Reply:
A
where “XX” is the program number minus one, and “YY” is the
channel number minus one.
“ZZZZ” and “TTTT” are the current “on” and “off” points of the
pulse, respectively.
“MM” specifies the scope of the change: “00” is the “off” edge;
“01” is the “on” edge; “02” is both edges of the pulse; and “03” is
all edges of all pulses in the channel. All values are in hex.
29
Dec Spt
Retards one edge of a pulse, both edges, or all pulses in a
channel, by one scale factor increment.
Cmd:
! ADR 29 XX YY ZZZZ TTTT MM CSM
Reply:
A
where “XX” is the program number minus one, and “YY” is the
channel number minus one.
“ZZZZ” and “TTTT” are the current “on” and “off” points of the
pulse, respectively.
“MM” specifies the scope of the change: “00” is the “off” edge;
“01” is the “on” edge; “02” is both edges of the pulse; and “03” is
all edges of all pulses in the channel. All values are in hex.
30
Def Disp
Default display on start-up.
Put:
! ADR 30 P XX CSM
Reply:
A
Get:
! ADR 30 G CSM
Reply:
A XX CSM
where “XX” is the display mode: “00” is Speed, “01” is Position,
and “02” is Auto.
31
Tog RPM
Toggle RPM speed.
Put:
! ADR 31 P XXXX CSM
Reply:
A
Get:
! ADR 31 G CSM
Reply:
A XXXX CSM
where “XXXX” is the toggle RPM speed in hex.
57
Rate Setup
Multiplier and units for RPM display.
Put:
! ADR 57 P XX YY CSM
Reply:
A
Get:
! ADR 57 G CSM
Reply:
A XX YY CSM
“XX” is the multiplier: “01” = 1X; “02” = 2X; “03” = 3X; “04” = .5X.
“YY” = units: “00” = RPM; “01” = BPM; “02” = CPM
Serial Commands (cont’d)