Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

to plug into the top or bottom connector. When the pump is signalled to run a pressure
will be indicated on this test gauge and should read at least 0.5 to 1.2 bar before the
pump will move. A pressure at the top fitting will indicate the pump should move
down. A pressure reading at the bottom fitting will indicate the pump should move up.

If no pressure is observed under these circumstances it is necessary to trace the air
circuit to locate the restriction and rectify. The digital indicator on the electro
pneumatic regulator in bay 2 should indicate the pressure being fed to the air cylinder.