beautypg.com

Magnum Venus Plastech Megaject RTM Pro Revison 7_0 User Manual

Page 14

background image

Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

Figure 2.5 – Main menu screen

2.4. Priming the system

In order to correctly prime the resin and catalyst systems, it is necessary to operate the
machine in recirculation mode. To navigate to the recirculation screen illustrated in
Figure 2.6, press the RECIRCULATION button on the main menu screen.

Figure 2.6 – Recirculation screen

Press the Recirculation on time button, and enter 15 on the numeric keypad shown in
Figure 2.7 and then press return. Then enter a recirculation off time of 1 minute and
an initial recirculation rate of 10%.

Press the START button on the screen housing to start the machine. The sounder
beacon will operate to warn the operator the machine is about to start, and then the
pumps should start to recirculate.

If the pumps do not move, increase the recirculation rate. If the pumps are
recirculating too quickly, reduce the recirculation rate. If the pumps do not move at
all, when a recirculation rate of 100% has been entered, please refer to sections 3.4
and 4.1 for further information as it is possible that configuration settings may be
incorrectly set.