Magnum Venus Plastech Megaject RTM Pro Revison 7_0 User Manual
Page 58

Megaject RTM Pro Manual – Revision 7.00 – 13
th
APRIL 2006
The RESET button for each motor will send an initialisation string to reset the motor.
This can be used to aid motor maintenance procedures. Please note; if a RESET
button is pressed the motors MUST be re-homed before the machine is operated.
The series of flags, labelled Bk through to Bt are status flags for each motor. The
meaning of each flag is described in Table 6.11.1.
The HOME button allows the operator to re-home the motors to the 0.5% catalyst
position. This button can be used to clear a “Motor reference lost – re-home motors”
fault.
The + button allows the user to increment the catalyst percentage; the motors will
move to update the position.
The – button allows the operator to decrement the catalyst percentage.
In combination, the + and – buttons allow the user to drive the motors up and down
the ratio arm to test the ratio drive is moving freely and as expected.
Motor System
State Flag
Event
Bk
EEPROM I/O error
Ba
Over current
Bs
Syntax error
Bu
User array index error
Bd
Math overflow occurred
Bm
Negative limit
Bp
Positive limit
Bx
Index
Bo
Motor off
Bh
Overheat
Be
Position error
Bw
Position wrap around
Bi
New index available
Bl
Negative limit crash
Br
Positive limit crash
Bt
Trajectory in progress
Table 6.11.1 – Servo Step motor status flags
6.10.2. I/O check screen
The I/O check screen, which can be seen in Figure 6.11.2, has been provided to give
the user access to all of the digital and analogue input signals. By pressing either the
up or down arrows, the operator can scroll through list of machine inputs and monitor
their values.