Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

The RESET button for each motor will send an initialisation string to reset the motor.
This can be used to aid motor maintenance procedures. Please note; if a RESET
button is pressed the motors MUST be re-homed before the machine is operated.

The series of flags, labelled Bk through to Bt are status flags for each motor. The
meaning of each flag is described in Table 6.11.1.

The HOME button allows the operator to re-home the motors to the 0.5% catalyst
position. This button can be used to clear a “Motor reference lost – re-home motors”
fault.

The + button allows the user to increment the catalyst percentage; the motors will
move to update the position.

The button allows the operator to decrement the catalyst percentage.

In combination, the + and buttons allow the user to drive the motors up and down
the ratio arm to test the ratio drive is moving freely and as expected.

Motor System
State Flag

Event

Bk

EEPROM I/O error

Ba

Over current

Bs

Syntax error

Bu

User array index error

Bd

Math overflow occurred

Bm

Negative limit

Bp

Positive limit

Bx

Index

Bo

Motor off

Bh

Overheat

Be

Position error

Bw

Position wrap around

Bi

New index available

Bl

Negative limit crash

Br

Positive limit crash

Bt

Trajectory in progress

Table 6.11.1 – Servo Step motor status flags

6.10.2. I/O check screen

The I/O check screen, which can be seen in Figure 6.11.2, has been provided to give
the user access to all of the digital and analogue input signals. By pressing either the
up or down arrows, the operator can scroll through list of machine inputs and monitor
their values.