Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

If the alarm continues to be generated, a suitably trained maintenance technician
should be informed.

Acknowledge the fault to clear it.

5.10. Catal alarm!

This alarm is raised if the flow of catalyst is under the threshold specified in the Catal
alarm configuration screen (see section 4.3). This alarm is has been designed to
prevent the operator from producing an under-catalysed part, due to incorrect machine
setup or failure of catalyst fluid system.

To clear the alarm, acknowledge it when the catalyst flow has risen above the
threshold level.

5.11. Cat over pressure

If the catalyst fluid system exceeds a safe operating pressure, this alarm will be
displayed. A suitably trained technician must ensure the catalyst line is free form
blockages etc.

Correct the fault to clear the alarm.
This alarm will stop the machine and prevent it from being started.

5.12. Air pressure < 5 bar

The machine must operate on an air pressure of between 5 – 7 bar. Adjust the
regulator in bay 2 to clear this fault.

This alarm will prevent the operator from starting the machine.

5.13. Air pressure > 7 bar

See 5.12.

5.14. Resin low

If a resin level sensor is connected and enabled in the resin alarms configuration
screen (see section 4.4), this alarm will be displayed if an injection is started with
insufficient resin available.

Top-up the resin supply to clear the alarm.
This alarm will prevent the operator from starting the machine.

5.15. Catalyst level low

If the catalyst level is too low when an injection is commenced, this alarm will be
triggered and the injection will be prevented from starting.

To clear the alarm, top-up the catalyst container.
This alarm will prevent the operator from starting the machine.