beautypg.com

Magnum Venus Plastech Megaject RTM Pro Revison 7_0 User Manual

Page 59

background image

Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

Toggle buttons are provided to test the follows outputs:

Flush sequencer valves 1 to 4

Head position valves

Autosprue open/close signal


The user must ensure that all valves are off (grey) before leaving this screen;
otherwise unexpected machine operation may occur.

Figure 6.11.2 – I/O check screen

6.10.3. Diagnostics


The diagnostics screen gives information regarding the Allen Bradley PanelView Plus
600 human machine interface (HMI). This screen is illustrated in Figure 6.11.3 and
should only be used by Plastech employees or under the direction of a Plastech
representative.

Figure 6.11.3 – Diagnostics display