beautypg.com

Magnum Venus Plastech Megaject RTM Pro Revison 7_0 User Manual

Page 44

background image

Megaject RTM Pro Manual – Revision 7.00 – 13

th

APRIL 2006

5.16. Solvent level low

If the solvent level is too low when an injection is commenced, this alarm will be
triggered and the injection will be prevented from starting.

To clear the alarm, top-up the solvent container.
This alarm will prevent the operator from starting the machine.

5.17. Motor reference lost – re-home

When the machine is initialised at start up, the motors are homed to establish an index
position. If the motors use this reference during operation, this alarm is displayed.

To clear the alarm, home the motors.
This alarm will prevent the operator from starting the machine.

5.18. Head valve position fault

Before and after an injection, the head valves will move from recirculate to inject and
vice versa. These valves are electrically monitored to ensure that they are in the
correct position. If the position of either the resin or catalyst valves is incorrect, this
alarm will be triggered.

This alarm will stop the machine and prevent the operator from starting the machine.