Lcr specifications – Liquid Controls LCR Setup & Operation User Manual
Page 5

5
LCR Specifications
The LectroCount LCR is a microprocessor based electronic register that offers the same advanced operation as previ-
ous LectroCount models but with additional benefits. The LectroCount LCR features include:
•
Full Weights & Measures Approvals
•
Class I, Division 1, Group C, D safety approvals.
•
NEMA 4X enclosure, Weights & Measures sealable
•
Five conduit connections
•
Operation with most flowmeters. LCR accept s input from PD, Amplified Turbine, Electromagnetic, and Mass
flowmeters.
•
Multi-Point Calibration for improved meter accuracy over the full flow range
•
Multiple Product Calibration
•
Optional Electronic Temperature Volume Compensation (ETVC)
•
Large character, backlit LCD display
•
10 digit totalizer
•
Two control buttons provide:
•
"SELECT" for accessing internal menus
•
"INCREASE" for adjusting internal programmable data
•
Push button presetting, rate of flow indication, temperature indication, product selection and more.
Specifications
Environmental:
Enclosure:
Class I, Division 1, Group C & D
NEMA 4X
Operating Temp. Range:
-40° to 158°F (-40° to 70°C)
Approvals:
US Weights & Measures
NTEP COC 86-022
Canada Weights and Measures AV2342
Communications:
RS232/485, Lap Pad
Hand Held, PC
Printer:
Epson, Okidata, and Blaster Models
Electrical:
Power:
+9 to 28 VDC, 3A Maximum (including solenoid
valves)
Inputs:
Temperature Input: 4-Wire Platinum RTD
Pulse Inputs:
+5 to 28-volt peak to peak, open collector
Single Channel or Quadrature
0-1500 Hz per Channel
Outputs:
Control Valve (2):
Open drain transistor for 2-stage valve control,
1 A Max. per channel
Auxiliary (2):
Open drain transistor for general-purpose
auxiliary control. Aux (1), 1 A Max
Aux. (2), 150 mA Max.
Scaled Pulse Output: Open drain output, 1 A Max.