Diagnostics/factory calibration, Diagnostics – Liquid Controls LCR Setup & Operation User Manual
Page 29

29
Diagnostics/Factory Calibration
Most of the DIAGNOSTICS fields are for DISPLAY ONLY. They contain information that can be useful in troubleshooting.
DIAGNOSTIC MESSAGES^
This field allows an operator to check pending diagnostic messages. Press ENTER and the cursor will
drop to the second line of the screen. Press LLLLL to scroll through the list of messages. The last message
is "END OF LIST".
SUPPLY VOLTAGE
The field shows the current supply voltage. The correct operating voltage is +9 to +28 VDC. DISPLAY
ONLY. NOTE: Voltage above +17 VDC will not indicate correctly.
Press LLLLL to advance to:
SOFTWARE
The software number is shown here. This number is critical for any troubleshooting discussions with the
Liquid Controls factory service personnel. DISPLAY ONLY.
LANGUAGE
The software number designating language selection (English, Spanish, etc.) is displayed here. DISPLAY
ONLY.
TICKET
The software number designating the ticket format is displayed here. DISPLAY ONLY.
Press LLLLL to advance to:
GROSS COUNT
This field displays a running total of the gross number of units for the current delivery. DISPLAY ONLY.
RATE
This field displays the actual flow rate. DISPLAY ONLY.
UNITS
This field displays the units of measure for flow total.
RATE BASE
This field displays the time base for flow rate.
Press LLLLL to advance to:
DIAGNOSTICS
Diagnostics - Screen 1
SUPPLY VOLTAGE
13.5
DIAGNOSTIC MESSAGES^
TVC ACTIVE
Diagnostics - Screen 2
TICKET
ST200v1.05
LANGUAGE
SL200v1.04
SOFTWARE
SR210v1.00
Diagnostics - Screen 3
RATE BASE^
PER MINUTE
UNITS^
GALLONS
RATE
0.0
GROSS COUNT
0