Recalibration/Proving without a Lap Pad

SINGLE POINT RECALIBRATION/PROVING CONTINUED

Press SELECT to advance to:

Calibration - Screen 1, Product Number

The current active Product Number is displayed. If a delivery is not active, the digit will be flashing, indicating

that it can be changed. Press INCREASE to scroll through the options. These options are labeled Prod 1,
Prod 2

, Prod 3, and Prod 4. When the desired option has been chosen, press SELECT. This will advance the

display to Calibration - Screen 3, Flow Rate.

NOTE

: If the display is NOT flashing, it cannot be changed. Press INCREASE to stop delivery and advance to

Calibration - Screen 5, Editable Prover Quantity

.

Calibration - Screen 3, Flow Rate

This displays the current flow rate through the meter . The display will update every ½ second. The unit of

measure is not displayed on the LCD, but appears directly below the display on the face of the LCR.

This

screen is DISPLAY ONLY. If a delivery is active, press INCREASE to stop delivery and advance to Calibration
- Screen 5, Editable Prover Quantity

.

Press SELECT to advance to:

Calibration - Screen 4, Temperature

This display shows the current temperature of fluid moving though the meter. Values will be shown in degrees

Celsius or Fahrenheit. The display updates every ½ second. DISPLAY ONLY. If a delivery is active, press
INCREASE

to stop delivery and advance to Calibration - Screen 5, Editable Prover Quantity.

Press SELECT to return to Calibration - Screen 1, Prover Quantity.

Calibration - Screen 5, Editable Prover Quantity

The Prover Quantity is displayed with the most significant digit flashing. The most significant digit appears in

the left most position of the display. If the two most significant digits are 98 or 99, a leading 0 will be displayed.

To change the value of this digit, press INCREASE. Each time INCREASE is pressed, the digit increases by a

value of 1. Once the number 9 has been reached, pressing INCREASE again will roll the digit back to 0. Once

the desired number is chosen, press SELECT to move one digit to the right.

P r o d 1

F 7 0 . 0

23.8 ºF

101.323