Appendix a - compensation types & parameters – Liquid Controls LCR Setup & Operation User Manual
Page 45

45
Appendix A - Compensation Types & Parameters
The table below shows the supported methods of calculating the Volume Correction Factor (VCF). The method is
independently selectable for each product in Product Calibration. The table below shows the valid temperature
ranges for each table. The hold temperature, T
hold
, is the temperature that VCF is held at for temperatures < T
hold
and
> T
min
. This is done to allow compensation in very cold environments where further extrapolation of equations is not
allowed.
General
Linear
Linear
0 to 0.003
ºC
15
-90
N/A
+100
General
Linear
Linear
0 to 0.005
ºF
60
-130
N/A
+212
LPG
USA
LPG
Europe &
Canada
Refined
Petroleum
Products
Europe &
Canada
Refined
Petroleum
Products
USA
General
API Table 54C
Coefficient
0.000486 to
0.001674
ºC
15
-50
-40
+95
Lube Oil
Europe &
Canada
Ammonia
Canada
Density
kg/m3
Density
kg/L
T
base
T
min
T
hold
Product
VCF Type
Parameter
Coefficient
Range
T
max
API Table 24
Specific
Gravity
0.5 to 0.550
ºF
60
-50
-50
+140
Scale
ºC or ºF
API Table 54
0.5 to 0.600
ºC
15
-46
-46
+60
API Table 54B
653.0 to 1075.0
ºC
15
-50
-40
+95
-50
-40
+200
API Table 6B
API Gravity
0 to 85
ºF
NH
3
N/A
N/A
60
Density
kg/m3
API Table 54D
800 to 1164
ºC
15
ºC
+40
-50
-40
+95
15
-30
-30