Lap Pad Calibration & Set-up

STEP 6: PRODUCT CALIBRATION CONTINUED

PT^

This field is used to calibrate the meter/register at up to 10 dif ferent flow rates for each product type/

calibration.

PROVER QTY

This field needs to contain the exact volume in the prover tank tested at actual flow rate. When an entry

is made, the actual %ERROR (delivery) against the base number will be recalculated automatically.

UNITS^

Choose the units of measure to be displayed. The choices are GALLONS, LITRES, CUBIC M, LBS

(pounds), KGS (kilograms), BARRELS, or OTHER. Use the KL

KL

KL

KL

KL

keys to scroll through the choices.

Press ENTER to make a selection.

%ERROR

This field contains the %ERROR difference against the base number.

LINEAR^

Select SETUP for single-point calibration or when setting up multi-point calibration. Select APPLIED to

activate multi-point calibration.

NOTE

: See p ages 23-24 for optional multi-point calibration instructions. If your LCR is set up for

single-point calibration, this concludes the Initial Calibration and Set-up procedures. Proceed to Page

25 for BASIC OPERATION instructions.

The next section covers Multi-Point Calibration.

PT^

1

Product Calibration - Screen 8

LINEAR^

SETUP

%ERROR

0.000

UNITS^

GALLONS

PROVER QTY

0.000

x 100

(Prover Qty - Meter Qty)

Prover Quantity

%Error =